| Categories: IT Infrastructure, Data Center, Uninterruptible Power Supply (UPS)
Availability is the name of the game when it comes to IT systems. While it''s impossible to predict, much less prevent, every unplanned outage, organizations can take steps to reduce the risk. That''s why uninterruptible power supplies (UPS) are essential IT infrastructure components across businesses of all sizes.
A UPS traditionally provides two things:
They have built-in mechanisms for detecting power outages and voltage drops and rapidly switching to battery backup yond that basic definition, UPSs vary widely in terms of:
The power load the UPS is supporting has a lot of influence on the differences between units. A single rack-mounted UPS could keep equipment running for an hour or more for the lowest-density racks. However, in the data center context, the power load is so high that operators can''t rely on UPSs alone. They typically need their UPS to run just long enough for generator power to come online. At a minimum, the UPS needs to provide enough power to ensure the safe shutdown of systems. Although, most data centers today can''t afford a millisecond of downtime.
The capital and operating costs of uninterruptible power supplies often represent significant line items in the IT budget. This buying guide offers criteria for evaluating UPSs to help you get the most value for your investment.
The size and weight of a UPS is primarily dependent on power requirements. Data center UPSs often look like standard 42U racks because of the enormous loads they''re expected to support, while traditional network closets and server rooms typically only need one or two 2U rack-mounted UPS. The type of battery also influences the UPS'' size and weight; lead-acid batteries are heavier than lithium (lithium batteries vs. lead-acid batteries). The factors below directly influence UPS size and weight.
Rack mount UPSs are designed to fit within the standard 19-inch racks commonly used in data centers, server rooms, network closets, and edge environments. They come in a range of sizes up to 10 kVA+. Rack mount units simplify maintenance and management, helping to maximize uptime and business continuity. Furthermore, rack mount units eliminate the single point of failure associated with one larger UPS. After all, redundancy is the magic word for network design. In the era of 24/7 connectivity, organizations can''t spare a second of downtime.
Purchase price is just one factor in the total cost of ownership (TCO) of a UPS. Organizations should consider these eight factors before making a purchasing decision.
There are three common UPS topologies: offline (standby), line-interactive, and online (double-conversion). The most basic, cheapest option is offline (standby), and the most advanced, premium option is online (double-conversion). In a separate piece (linked above), we dive more into the differences between online, line-interactive, and offline UPSs, but the main difference concerns power conditioning. Online UPSs provide the maximum level of protection against power sags, spikes, and under/over voltage.
While the lifespan of a UPS is about ten years, some batteries must be replaced after just three to five years. The cost of additional batteries and the labor involved in replacing them adds to the TCO calculation. There may also be battery disposal costs.
Traditional valve-regulated lead-acid (VRLA) batteries require up to 24 hours to fully recharge, while lithium-ion batteries recharge in just two hours. VRLA batteries typically provide 200 discharge cycles, meaning you can deplete and recharge the battery 200 times before it fails. Lithium-ion batteries offer 500 to 7,000 discharge cycles depending upon the chemistry and have a slow rate of discharge when not in use.
One of the biggest factors affecting battery life is operating temperature. The recommended operating temperature for VRLA batteries is 68 degrees to 77 degrees Fahrenheit, while lithium-ion UPSs can operate at up to 140 degrees Fahrenheit without affecting the battery''s lifespan. The need to cool a UPS adds to data center operational costs and thus the TCO of the UPS. Some battery compositions, such as nickel-cadmium, are designed to operate effectively in high-heat environments.
UPS batteries are "trickle charged" — enough electricity is supplied to offset the battery''s self-discharge rate and keep the battery fully charged. Some batteries lose more energy during trickle charging than others and thus consume more electricity during "float" or standby mode. "Load shedding" allows users to power down noncritical receptacles, leaving the receptacles with critical equipment operational.
An uninterruptible power supply with a built-in battery management system (BMS) provides status and fault monitoring, cell balancing, power optimization, and more, reducing the labor required for maintenance. It also helps reduce the risk of system downtime due to battery failure.
Best-in-class UPSs provide network connectivity for remote monitoring and management. This simplifies maintenance, thereby reducing TCO.
The sine wave refers to the waveform of the battery output. Some UPSs produce a pure sine wave, while others produce a simulated or modified sine wave. Because a pure sine wave is smoother and cleaner, it is preferred for critical and highly sensitive equipment. A modified sine wave provides rougher, less stable output but is adequate for PCs, A/V components, and other less-critical equipment. Online UPSs always produce a pure sine wave, but line-interactive and offline UPSs sometimes produce a modified sine wave.
When a UPS runs out of power, a technician typically has to go to the rack and manually reboot the UPS once primary power is restored. A UPS with an auto-restart feature does this automatically, reducing labor costs.
Enconnex offers a complete line of rack mount UPSs, including line-interactive and online (double-conversion) topologies with lead-acid and lithium-ion (LiFePO4) batteries. Power capacities range from 800 VA to 10 kVA to support a wide range of rack densities. All models provide pure sine wave output for maximum power reliability. Our UPSs offer industry-leading features, including smart displays for precise monitoring, hot-swappable battery packs, auto-restart, and more. Customers can bundle Enconnex UPSs with our line of EdgeRack micro data center cabinets for a complete, prefabricated solution. Contact one of our specialists for help choosing the right UPSs for your application.
Robert Faulkner is the Vice President of Engineering and Operations at Enconnex. He comes from a strong background in product management with over 20 years in the IT industry. He currently holds an MSME and CDCD certification. He earned his MS degree in Mechanical Engineering at University of Nevada, Reno.
Tags: IT Infrastructure, Data Center, Uninterruptible Power Supply (UPS)
Get to know Enconnex with a customized fit-out
Enconnex is a global data center and IT infrastructure product manufacturer known for developing innovative custom solutions and offering a variety of standard products, including server and network racks and cabinets, micro data centers, UPSs, PDUs, power products, containment, and more. Founded in 2013, Enconnex customers include some of the largest names in technology. With 70,000 square feet of manufacturing and warehousing space in Reno, NV, and a global team of experts dedicated to your success, Enconnex has the inventory available and logistics expertise to get you what you need when you need it.
Phone: +1 (775) 562-2138
Phone (Toll-Free): +1 (833) TALK-ECX
Fax: +1 (775) 644-3202
2700 Mill Street, Unit 400, Reno, NV 89502
In today''s digital age, server rooms are the backbone of businesses and organizations, housing critical data and ensuring uninterrupted access to services. To safeguard these mission-critical operations, it''s essential to invest in a reliable Uninterruptible Power Supply (UPS) system. In this comprehensive guide, we will explore the best UPS for server rooms, providing you with top picks and a detailed buyer''s guide to help you make an informed decision.
In the realm of server room management, the deployment of a reliable Uninterruptible Power Supply (UPS) system is nothing short of imperative. Let''s delve deeper into why having a UPS system in your server room is absolutely essential:
About Ups server backup
As the photovoltaic (PV) industry continues to evolve, advancements in Ups server backup have become critical to optimizing the utilization of renewable energy sources. From innovative battery technologies to intelligent energy management systems, these solutions are transforming the way we store and distribute solar-generated electricity.
When you're looking for the latest and most efficient Ups server backup for your PV project, our website offers a comprehensive selection of cutting-edge products designed to meet your specific requirements. Whether you're a renewable energy developer, utility company, or commercial enterprise looking to reduce your carbon footprint, we have the solutions to help you harness the full potential of solar energy.
By interacting with our online customer service, you'll gain a deep understanding of the various Ups server backup featured in our extensive catalog, such as high-efficiency storage batteries and intelligent energy management systems, and how they work together to provide a stable and reliable power supply for your PV projects.